Index

e-ISSN 1828-1427

 

Rivista trimestrale di Sanità Pubblica Veterinaria edita dall'Istituto Zooprofilattico Sperimentale dell'Abruzzo e del Molise ‘G. Caporale’

A quarterly journal devoted to veterinary public health, veterinary science and medicine published by the Istituto Zooprofilattico Sperimentale dell’Abruzzo e del Molise ‘G. Caporale’ in Teramo, Italy


Editorial policy
Copyright and disclaimers
Guidelines for Authors
Editors
Honorary Members
Editorial Board
Scientific Advisory Board
Associate Editors
Issues online
Tariffs
Contact
 

ISSUES ONLINE

2015 - Volume 51 (2), April-June
   
 
Mayurkumar P. Bhimani, Bharat B. Bhanderi & Ashish Roy  
Loop‑mediated Isothermal Amplification assay (LAMP) based detection of Pasteurella multocida in cases of haemorrhagic septicaemia and fowl cholera 115-121
doi: 10.12834/VetIt.242.812.4
 
Summary
Twenty two isolates of Pasteurella multocida were obtained from different tissues of dead birds and animals (cattle, buffalo, sheep, and goat) suspected of fowl cholera and haemorrhagic septicaemia. The isolates were confirmed as P. multocida by various biochemical tests and PM PCR. An attempt was made to standardize Loop mediated isothermal amplification (LAMP) using newly designed primer sequences of KMT1 gene. Loop mediated isothermal amplification was conducted using 6 sets of primers at 65°C for 30 minutes and the result was confirmed by visual observation using SYBR green fluorescence dye as marker of positive reaction under UV transilluminator. On electrophoretic analysis of the products on 2% agarose gel, a ladder like pattern was observed, which suggested a positive amplification, whereas no amplification was observed in negative controls. Additionally, product of positive reaction yielded a green fluorescence following addition of SYBR green under UV transilluminator. It was observed that LAMP is a more sensitive test than polymerase chain reaction (PCR), as the former could detect DNA to lower limit of 22.8 pg/µl, while the latter could detect DNA to lower limit of 2.28 ng/ µl, thus LAMP could detect 100 times lesser concentration of DNA in comparison to PCR. Loop mediated isothermal amplification is a rather newer molecular technique, which can be used for rapid detection of infectious agent at field level and which does not require sophisticated instrument, i.e. thermal cycler. Furthermore, unlike the conventional PCR technique, LAMP requires lesser time to perform and result can be read visually.

Keywords
Fowl cholera, Haemorrhagic septicaemia, Loop‑mediated Isothermal amplification (LAMP),
Pasteurella multocida, Polymerase Chain Reaction.


Full article

     
 
    © Istituto Zooprofilattico Sperimentale dell'Abruzzo e del Molise 2015